- Significance of NTA technology in their characterisation
- Applications and case studies
- Significance of dynamic light scattering as a complementary analytical technique for nanoparticle size, molecular weight and zeta potential analysis
- Nanoparticle size, molecular weight and zeta potential analysis using Dynamic Light Scattering with Zetasizer
- Nanoparticle size, concentration and fluorescence tracking using NanoSight Pro NTA *NEW*
- Sampling and sample preparation
- Best lab practices for superior data quality
- Anyone working with EVs
- Drug discovery scientists with an interest in drug design, medicinal chemistry and cancer biology
- Anyone with a keen interest to learn more about different characterisation methods
- EV applications in novel research from cancer research, disease management etc
- Characterisation techniques such as NTA (nanoparticle tracking analysis), Dynamic Light Scattering etc
- Latest in NTA technology, with the launch of NanoSight Pro. Look forward to cutting edge advancements in fluorescence and wide range of thermal control; enabling greater sensitivity and insights to your EVs
- 6 May (Melbourne, Deakin): EV applications and characterisation workshop
- 7 May (Melbourne, RMIT): EV applications and characterisation workshop
- 8 - 12 May (Melbourne): ISEV conference
- 13 May (Brisbane, University of Queensland): EVs in neurodegenerative diseases
- 14 May (Sydney UNSW): EV applications and characterisation workshop
- 16 May (National University of Singapore): NTA Characterisation & Data Analysis
- 17 May (National University of Singapore): Extracellular Vesicles applications and characterisation workshop
- 20 May (Thailand, Bangkok): NTA Characterisation & Data Analysis
- 21 May (Thailand, Bangkok): EV applications and characterisation workshop
Extracellular Vesicles Applications and Characterisation Workshop (Sydney, UNSW)
14 May 2024 | University of New South Wales, Chemical Sciences Building (F10)
About The Event
Extra-cellular microvesicles and exosomes are found to be of great importance in the development and diagnosis of a wide range of disease states. For instance, from cancer to diabetes treatments. Found to be generated by nearly all cells and in all organisms, they are believed to contain a wide range of signalling proteins as well as genetic material of many different types. Their detection has, to date, only been possible by electron microscopy or by classical methods of analysis such as DLS. Conventional flow cytometry has a lower limit in practice of some 300nm and therefore cannot see the majority of microvesicular material thought to be present. NTA offers a means by which not only can such structures be seen and concentration measured, but variations in the technique, such as fluorescence mode NTA, have allowed exosomes to be phenotyped. This multi-parameter capability, compatible with natural structures in their native environment promises to be of significant value in the elucidation of the role these structures play. Malvern Panalytical and our Australia partner - ATA Scientific, are proud to bring you an EVs applications and characterisation workshop. There will be guest talks by international scientists as well as our scientist from the supply center in Malvern UK. Look forward to the launch of our latest NTA technology which will be on display at the tour and ISEV conference too. This workshop marks the Australia-leg of our international tour. Book an appointment to meet our specialist as she hosts workshops in Melbourne, Sydney and Brisbane.
More Information
Programme
Time |
Programme |
Speaker |
09:30 |
Using exosomes & extracellular vesicles as biomarkers |
Dr Chen Yu-Su |
10:30 |
|
Dr Guang Li |
11:00 |
Tea break |
|
11:15 |
Live demo rotations in small groups every 30mins |
Dr Chen Yu-Su Dr Guang Li |
12:15 |
Lunch |
|
13:00 |
Recap / Q & |
|
13:15 |
Practical hands-on: - Data analysis with the smart software using the NS Pro Xplorer |
Dr Chen Yu-Su |
14:00 |
Tea break |
|
14:10 |
- Data analysis continued (how to spot bad data and how to achieve superior data quality) |
|
15:00 |
Q & A |
|
15:00 |
One-on-one discussions |
Chen Yu-Su |
16:00 |
End |
Who should attend?
What will you learn?
Be part of our international roadtrip
