- Instructor will communicate the agenda, all course materials
- This course is intended to be very interactive
- Your technical questions are welcomed and encouraged
- Course materials will be emailed as pdfs post course
Wavelength Dispersive XRF SuperQ6 User Training - USA and Canada
September 10 - 12, 2024 | 9:00-17:00 In Person
Westborough MA
THIS CLASS IS SOLD OUT
About The Event
Malvern Panalytical is pleased to offer this 3-day in person course based on lectures and demonstrations on the theoretical aspects of X-ray fluorescence analysis using the Zetium sequential wavelength dispersive spectrometer. Emphasis is placed on setting up traditional quantitative XRF applications, calibration and daily use of SuperQ. Theoretical aspects of parameter selection, matrix effects, sample preparation and routine measurements, calibration and calibration update, monitor correction and assessment of measurement results are treated in detail along with practical demonstrations. An introduction to the Omnian standardless software is included. The following aspects will be covered during the course: - Theory of X-ray fluorescence and instrumentation - Qualitative and Quantitative analysis - Application Setup - Calibration, Matrix effect and Sources of errors - Performing measurements - Drift monitors, their implementation and practical use - Introduction to Omnian standardless analysis - Sample preparation of fused beads, pressed pellets, loose powders and liquids This is a paid course, we are offering a 50% discount to academic and government. If you have a valid training course voucher, please enter it during registration, pay via credit card or provide PO to trainingUSA@malvernpanalytical.com so it can be approve. Please note, vouchers have no cash value and cannot be exchanged, refunded, or returned. To register with a voucher only: • Click register • Under registration pick “Comp voucher” • Click order now button • Fill out your details, including voucher number and submit Do not use this option if you do not have a voucher, you will not be registered. Complimentary breakfast snack and lunch will be provided. The customer is responsible for all other costs of hotel, transportation, and additional meals outside of what is provided. Course registration will close two weeks prior to the course date or as soon as the class is full. It is encouraged that participants come with questions unique to their applications and, if possible, example data to be assessed during the course. This is a popular course, please don't wait to register.
More Information
Location:
Malvern Panalytical Office and Lab
2400 Computer Drive, Suite 2100
Westborough MA 01581
Things to note:
We reserve the right to cancel courses due to insufficient enrollment or unforeseen circumstances. Please note, this is a USA based course and will be provided in English. All payments must be made in USD, with credit card, purchase order or voucher. Recordings of the sessions are not permitted. Pricing is subject to change.