- Instructor will communicate the agenda, all course materials
- This course is intended to be very interactive
- Your technical questions are welcomed and encouraged
- Course materials will be emailed as pdfs post course
- We reserve the right to cancel any course or individual registration in the event of low enrollment or other unforeseen circumstances. Please note that this is a course held in the United States.
- Preference may be given to participants located near the course venue and to existing customers.
- By registering, you agree to attend. If you need to cancel, timely notice is required; failure to do so may limit your ability to register for future courses.
Wavelength Dispersive XRF SuperQ6
User Training for USA and Canada
September 15-17, 2026 | 9AM - 5:00PM ET
In Person
Westborough MA
About The Event
Malvern Panalytical is pleased to offer this 3-day in person course based on lectures and demonstrations on the theoretical aspects of X-ray fluorescence analysis using the Zetium sequential wavelength dispersive spectrometer. Emphasis is placed on setting up traditional quantitative XRF applications, calibration and daily use of SuperQ. Theoretical aspects of parameter selection, matrix effects, sample preparation and routine measurements, calibration and calibration update, monitor correction and assessment of measurement results are treated in detail along with practical demonstrations. An introduction to the Omnian standardless software is included. The following aspects will be covered during the course: • Theory of X-ray fluorescence and instrumentation • Qualitative and Quantitative analysis • Application Setup • Calibration, Matrix effect and Sources of errors • Performing measurements • Drift monitors, their implementation and practical use • Introduction to Omnian standardless analysis • Sample preparation of fused beads, pressed pellets, loose powders and liquids Complimentary breakfast snacks and lunch will be provided. The customer is responsible for all other costs of hotel, transportation, and additional meals outside of what is provided. Course registration will close one week prior to the course date or as soon as the class is full. It is encouraged that participants come with questions unique to their applications. This is a popular course, please don't wait to register.
More information
Location:
Malvern Panalytical Office and Lab
2400 Computer Drive, Suite 2100
Westborough MA 01581
Hotel Suggestions:
Hampton Inn Boston - Westborough
15 Connector Road, Westborough, MA 01581
Phone: (508) 329-5570
DoubleTree by Hilton Boston – Westborough
5400 Computer Drive, Westborough, MA 01581
Phone: 508-366-5511
Disclaimer
If the course reaches capacity, you may join the waiting list. We may offer an additional session to those on the waitlist, but we encourage you to secure a seat in the next available course. Please go to Webinars and Events to view full schedule of courses.