- Instructor will communicate the agenda, and all course materials,
- This course is intended to be very interactive
- Your technical questions are welcomed and encouraged
- Course materials will be emailed as pdfs post course
Epsilon XRF User Training USA and Canada
April 21-23, 2026 | 9AM - 5PM Eastern
Westborough, MA
About The Event
Malvern Panalytical is pleased to offer this 3-day in person course on the fundamental and practical techniques of X-ray Fluorescence analysis using the Epsilon 1, Epsilon 3, and Epsilon 4 in this course. Particular emphasis is placed on the practical use of the spectrometer in conjunction with its software. Practical aspects of parameter selection, matrix effects, sample preparation, qualitative and quantitative analysis, standardless analysis using Omnian, calibration and analysis results are addressed extensively. The following aspects will be covered during the course: - Physics of X-rays - The X-ray spectrometer - SSD detector and its properties - Instrumental parameters - Statistics - Matrix effects - Sample preparation - Set up application including calibration - Measurement of unknown samples - Standardless analysis Complimentary breakfast snacks and lunch will be provided. The customer is responsible for all other costs of hotel, transportation, and additional meals outside of what is provided. Course registration will close one week prior to the course date or as soon as the class is full. It is encouraged that participants come with questions unique to their applications. This is a popular course, please don't wait to register.
More Information:
Location:
Malvern Panalytical Office and Lab
2400 Computer Drive, Suite 2100
Westborough MA 01581
Hotel Suggestions:
Hampton Inn Boston - Westborough
15 Connector Road, Westborough, MA 01581
Phone: (508) 329-5570
DoubleTree by Hilton Boston – Westborough
5400 Computer Drive, Westborough, MA 01581
Phone: 508-366-5511
Things to note:
Disclaimer:
We reserve the right to cancel any course or individual registration in the event of low enrollment or other unforeseen circumstances. Please note that this is course held in the United States.
Preference may be given to participants located near the course venue and to existing customers.
By registering, you agree to attend. If you need to cancel, timely notice is required; failure to do so may limit your ability to register for future courses.
If the course reaches capacity, you may join the waiting list. We may offer an additional session to those on the waitlist, but we encourage you to secure a seat in the next available course. Please go to Webinars and Events to view full schedule of courses.
