- Instructor will communicate the agenda, course materials, and any necessary software links to take part in this course.
- This course is intended to be very interactive and welcomes participation.
- Your technical questions encouraged.
Powder Flow: FT4 User Training
USA & Canada
April 22, 2026 | 9AM - 5PM EDT | In Person
Norcross, Georgia
About The Event
Malvern Panalytical is pleased to offer this one day in-person training course at our facility in Norcross, Georgia. This course will be focused on hands-on operations of powder flow characterization technology and interpretation of results/data analysis. Who Should Attend: Technicians, analysts, lab managers, researchers, and anyone needing to operate and/or interpret and understand results generated from a powder flow analyzer should attend this course. The course will utilize the latest Freeman Technology® Powder Rheometer model, but most course material is also applicable to users of other powder flow instrumentation. The course is extremely beneficial to the entry-level operator and moderately experienced users wishing to expand their capability. Preparation: A course packet consisting of recorded lectures and e-learning modules must be completed prior to arrival. These will be distributed by the instructors electronically one week prior. The time spent in person with our instructors will focus on practical elements. Prior hands-on experience with the instrument is helpful but not required to attend. Background: The FT4 Powder Rheometer® provides flowability characteristics of powders and bulk solids materials. This includes various conditions for the powder ranging from high-stress, tightly packed states to loosely packed or fluidized states. These various analyses help identify different material properties such as cohesiveness, effects of friction, shape effects, density, etc. The wide range of analyses make these studies applicable to a wide range of powder handling processes including but not limited to design of storage bins & hoppers, fluidized beds, tablet presses, powder bed fusion, formulation development and additives, and more. Curriculum: • The instrument components and overview of accessories • Sample preparation, including loading and conditioning a sample • Additional considerations for specific samples that require non-standard sample prep • Hands-on testing procedures, including: • Dynamic Flowability Characterization, Bulk density, Permeability, Fluidization, Shear cell testing, and Wall Friction analysis • An overview of data interpretation and reporting options • The customization of testing methods and discussion of appropriate procedures for modifications • Demonstration of best practices, tips & tricks, and cleaning procedures • Operator Maintenance with a member of our Service Department to discuss troubleshooting and user-maintenance • Calibrations procedures Complimentary breakfast snacks and lunch will be provided. The customer is responsible for all other costs of hotel, transportation, and additional meals outside of what is provided. Course registration will close one week prior to the course date or as soon as the class is full. This course has limited seating, please don't wait to register.
More Information:
Things to know:
Location:
Micromeritics
4356 Communications Drive
Norcross, Georgia 30093, USA.
Suggested Hotel(s):
The suggested hotels are located less than 3 miles from the Micromeritics Corporate Headquarters. Micromeritics has negotiated special rates with the hotels listed below. When you contact them, please be sure to mention that you are requesting the Micromeritics Corporate Rate.
Atlanta Marriott Peachtree Corners
475 Technology Pkwy NW, Peachtree Corners, GA
Phone: (770) 263-8558
Courtyard by Marriott Atlanta Duluth Downtown
3141 Hill St NW, Duluth, GA
Phone: (470) 740-1040
Residence Inn Atlanta Duluth/Gwinnett Place
1760 Pineland Road, Duluth, GA
Phone: (770) 921-2202
Hampton Inn and Suites Atlanta/Duluth
1725 Pineland Road, Duluth, GA
Phone: (770) 931-9800
Disclaimer:
We reserve the right to cancel any course or individual registration in the event of low enrollment or other unforeseen circumstances. Please note that this is course held in the United States.
Preference may be given to participants located near the course venue and to existing customers.
By registering, you agree to attend. If you need to cancel, timely notice is required; failure to do so may limit your ability to register for future courses.
If the course reaches capacity, you may join the waiting list. We may offer an additional session to those on the waitlist, but we encourage you to secure a seat in the next available course. Please go to Webinars and Events to view full schedule of courses.
