- Course trainer will communicate the agenda and a pdf copy of course materials will be provided
- This course is intended to be very interactive
- Your technical questions are welcomed and encouraged
Wavelength Dispersive XRF SuperQ6 User Training
September 19-21, 2023 | In Person
2400 Computer Drive, Suite 2100
Westborough, MA 01581
About The Event
Malvern Panalytical is pleased to offer this 3-day in person course based on lectures and demonstrations on the theoretical aspects of X-ray fluorescence analysis using the Zetium sequential wavelength dispersive spectrometer. Emphasis is placed on setting up traditional quantitative XRF applications, calibration and daily use of SuperQ. Theoretical aspects of parameter selection, matrix effects, sample preparation and routine measurements, calibration and calibration update, monitor correction and assessment of measurement results are treated in detail along with practical demonstrations. An introduction to the Omnian standardless software is included. The following aspects will be covered during the course: - Theory of X-ray fluorescence and instrumentation - Qualitative and Quantitative analysis - Application Setup - Calibration, Matrix effect and Sources of errors - Performing measurements - Drift monitors, their implementation and practical use - Introduction to Omnian standardless analysis - Sample preparation of fused beads, pressed pellets, loose powders and liquids This is a 3 day paid course, the rate is $805 per participant per day, currently we are offering a 50% discount to Academic and Government. To pay with a PO or If you have a valid voucher follow directions below, then forward PO or voucher to trainingUSA@malvernpanalytical.com so it can be approve. To register with a voucher: - click on the date and course you wish - click register - under registration pick “Comp voucher” - click order now button - fill out details, including voucher number and submit Do not use this option if you do not have a voucher, you will not be registered. Complimentary breakfast snacks and lunch will be provided; the customer is responsible for all other costs; hotels, transport, additional meals outside of what is offered. Course registration will close one week prior to the course date or as soon as the class is full. It is encouraged that participants come with questions unique to their applications and, if possible, example data to be assessed during the course. This is a popular course, please don't wait to register.
More Information
We reserve the right to cancel courses due to insufficient enrollment or unforeseen circumstances.
Please note, this is an in-person course located at our US Malvern Panalytical, located at 2400 Computer Drive, Suite 2100, Westborough MA 01581. The course will be provided in English. All payments to be made in USD. Recordings of the sessions are not allowed. Pricing is subject to change.