Omnian for standardless WDXRF elemental analysis User Training - USA & Canada
October 22-24, 2024 | 9:00-17:00 ET | In Person
Westborough, MA
About The Event
Malvern Panalytical is pleased to offer a 3 day in person course, based on lectures and demonstrations on the theoretical aspects of X-ray fluorescence analysis using Omnian. This course is intended for users familiar with the operation of the SuperQ software, but want an in-depth understanding of the Omnian standardless analysis option. Emphasis is placed on setting up and optimizing Omnian processing parameters, adding standards (tagging), calibration, adding channels and daily use of Omnian. Theoretical aspects of parameter selection, matrix effects, sample preparation and routine measurements, calibration, tagging, adding channels, monitor correction, and assessment of measurement results are treated in detail. The course is composed of lectures and demonstration sessions using the Zetium spectrometers available in our application laboratory in Westborough MA, USA. The following aspects will be covered during the course: - Theory of X-ray fluorescence and instrumentation - Omnian analysis - Omnian application setup - Calibration, Matrix effect and Sources of errors - Performing measurements - Drift monitors, their implementation and practical use - Adding standards to Omnian (tagging) - Adding channels to Omnian to improve sensitivity - Sample preparation of fused beads, pressed pellets, loose powders and liquids This is a paid course, currently we are offering a 50% discount to Academic and Government. To pay with a PO or If you have a valid voucher follow directions below, then forward voucher to trainingUSA@malvernpanalytical.com so it can be approved. To register with a voucher: - click on the date and course you wish - click register - under registration pick “Comp voucher” - click order now button - fill out details, including voucher number or PO and submit Do not use this option if you do not have a valid voucher. Course registration will close one week prior to the course date or as soon as the class is full. It is encouraged that participants come with questions unique to their applications and, if possible, example data to be assessed during the course. Complimentary breakfast snack and lunch will be provided. The customer is responsible for all other costs of hotel, transportation, and additional meals outside of what is provided.
More Information
Location:
Malvern Panalytical office
2400 Computer Drive, Suite 2100
Westborough MA
- Instructor will communicate the agenda
- This course is intended to be very interactive
- Your technical questions are welcomed and encouraged
- Course materials will be emailed as pdfs post course
We reserve the right to cancel courses due to insufficient enrollment or unforeseen circumstances. Please note, this is a USA based course and will be provided in English. All payments must be made in USD, with credit card, purchase order or voucher. Recordings of the sessions are not permitted.
Pricing is subject to change. Vouchers have no cash value and cannot be exchanged, refunded, returned or applied to other training.